Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. bras. cir. cardiovasc ; 33(4): 398-403, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-958424

ABSTRACT

Abstract Introduction: Carcinoid heart disease most frequently involves the tricuspid or, more rarely, the pulmonary valve and presents with right heart failure as 5-HT is metabolized by the lung. Left-sided valve involvement is quite rare. We describe our experience of 3 patients presenting with heart failure secondary to carcinoid heart disease affecting all four cardiac valves. There are only four previous isolated case reports in the literature. Methods: All three patients underwent quadruple valve replacement during a single operation. Right ventricular outflow tract reconstruction with a pericardial patch was performed in all patients. For 24 hours prior to surgery, all patients received intravenous octreotide, which continued in intensive care for at least 24 hours. Results: Mean cross-clamp and bypass times were 175 (range 164-197 minutes) and 210 (range 195-229 minutes) minutes, respectively. Mean intensive treatment unit (ITU) and inpatient stays were 2.3 (range 2-3 days) and 12 (range 9-16 days) days, respectively. One patient was reopened for bleeding 4 hours postoperatively from a ventricular pacing wire site. None required a permanent pacemaker postoperatively. There were no other complications in any patient. The quality of life was excellent at 6-16 months clinic follow-up as they were in NYHA 1. Postoperative echocardiography showed no paravalvular leaks and well-functioning prostheses in all cases. Conclusion: Surgery to replace all four valves is feasible with excellent medium-term survival and a very low rate of complications. Patients with carcinoid heart disease should always be considered for surgery irrespective of the extent of valvular involvement.


Subject(s)
Humans , Carcinoid Heart Disease/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Diseases/surgery , Bioprosthesis , Severity of Illness Index , Heart Valve Prosthesis , Carcinoid Heart Disease/diagnostic imaging , Echocardiography , Heart Valve Diseases/diagnostic imaging , Heart Valves/surgery , Heart Valves/diagnostic imaging
2.
Rev. bras. cir. cardiovasc ; 33(2): 169-175, Mar.-Apr. 2018. tab
Article in English | LILACS | ID: biblio-958397

ABSTRACT

Abstract Introduction: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. Methods: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. Results: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. Conclusion: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Postoperative Complications/etiology , Thrombocytopenia/etiology , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Platelet Count , Prosthesis Design , Time Factors , Cardiopulmonary Bypass/adverse effects , Retrospective Studies , Treatment Outcome , Constriction , Heart Valve Prosthesis Implantation/methods , Sutureless Surgical Procedures/adverse effects , Sutureless Surgical Procedures/methods
3.
Rev. bras. cir. cardiovasc ; 33(2): 122-128, Mar.-Apr. 2018. tab
Article in English | LILACS | ID: biblio-958395

ABSTRACT

Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). Results: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Aortic Valve Stenosis/surgery , Bioprosthesis/standards , Heart Valve Prosthesis/standards , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Postoperative Period , Prosthesis Design , Time Factors , Cardiopulmonary Bypass/methods , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Constriction , Sternotomy/methods , Sutureless Surgical Procedures/methods
4.
Rev. bras. cir. cardiovasc ; 33(1): 8-14, Jan.-Feb. 2018. tab
Article in English | LILACS | ID: biblio-897988

ABSTRACT

Abstract Objective: The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. Methods: From January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database and perioperative transoesophageal echocardiography findings were studied retrospectively. Results: Ninety-two patients underwent isolated aortic valve replacement (group A) with Perceval valve and 47 patients had combined procedures of aortic valve replacement and coronary artery bypass grafting (group B). The patients received a size S (n=23), M (n=39), L (n=42) or XL (n=35) prosthesis. Perceval valve was successfully implanted in 135 (97.1%) patients. Mean cross-clamping time and bypass time were 40 and 63 minutes for isolated cases, while 68 and 107 minutes for combined cases. Three (2.1%) patients died within 30 days. Four patients suffered stroke and 5 patients went into acute renal failure. Median intensive care unit and hospital stay was 2 and 8.5, respectively. Four valves were explanted due to significant paravalvular leak after surgery. Five patients had permanent pacemaker as a result of complete heart block and mean postoperative drainage was 295 mL for isolated case and 457 mL for combined cases. The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: Early postoperative results showed that Perceval valve is safe. Further follow up is needed to evaluate the long-term outcome with this bioprosthesis.


Subject(s)
Humans , Male , Middle Aged , Aged , Aged, 80 and over , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Sutureless Surgical Procedures , Heart Valve Diseases/surgery , Retrospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
5.
Ann Card Anaesth ; 2015 Oct; 18(4): 599-602
Article in English | IMSEAR | ID: sea-165277

ABSTRACT

The indication of pacemaker/AICD removal are numerous. Serious complication can occur during their removal, severe tricuspid regurgitation is one of the complication. The occurrence of PFO is not uncommon among adult population. Shunting across PFO in most circumstance is negligible, but in some necessitates closure due to hypoxemia. We report a case of 62 year old man, while undergoing AICD removal, had an emergency sternotomy for cardiac tamponade. Postoperatively, he experienced profound hypoxemia refractory to oxygen therapy. Transthoracic Echocardiogram was performed to rule out intracardiac shunts at an early stage, but it was difficult to obtain an good imaging windows poststernotomy. A small pulmonary emboli was noted on CTPA, but was not sufficient to account for the level of hypoxemia and did not resolve with anticoagulation. Transesophageal echocardiogram showed flail septal tricuspid valve with severe TR and bidirectional shunt through large PFO. Patient was posted for surgery, tricuspid valve was replaced and PFO surgically closed. Subsequently, patient recovered well ad was discharged to home. Cause of hypoxemia might be due to respiratory or cardiac dysfunction. But for hypoxemia refractory to oxygen therapy, transoesophageal echocardiogram should be always considered and performed early as an diagnostic tool in post cardiac surgical patients.

SELECTION OF CITATIONS
SEARCH DETAIL